This guide provides detailed solutions for common Lochinvar boiler issues, including error codes like E12, ARHL/MRHL, and lockout situations.
Lochinvar is a leading manufacturer of high-efficiency boilers and water heaters, renowned for their innovative designs and robust performance. Understanding the intricacies of these systems is crucial for effective troubleshooting; Lochinvar products, including the Knight, Copper-Fin II/IIE, and Crest series, utilize sophisticated controls and sensors to optimize operation.
Common issues often stem from ignition failures, flame detection problems, or communication errors within the Modbus system. Recognizing the significance of error codes – lockout, blocking, and notification types – is paramount. These codes provide valuable insights into the root cause of malfunctions. Furthermore, familiarity with component-specific diagnostics, such as flame sensor and igniter testing, is essential for pinpointing and resolving issues efficiently. Proper gas and electrical safety practices must always be observed when servicing Lochinvar equipment.
Understanding Lochinvar Error Codes
Lochinvar systems employ a comprehensive error code system to diagnose operational issues. These codes are categorized into Lockout, Blocking, and Notification types, each indicating a different severity and nature of the problem. Lockout codes signify critical failures requiring immediate attention, while Blocking codes represent operational interruptions. Notification codes provide status updates during normal running conditions.
Decoding these codes is the first step in effective troubleshooting. For example, alternating ARHL and MRHL codes often point to ignition or flame detection faults. The E12 error code, a frequently encountered issue, requires a simplified troubleshooting approach. Understanding the specific meaning of each code, as detailed in Lochinvar manuals, allows technicians to efficiently identify the faulty component or system. Analyzing fault messages displayed on the operator interface is also key.

Common Lochinvar Boiler Issues & Troubleshooting
Frequent problems include error codes (E12, ARHL/MRHL), low flame signals, lockouts, and blocking issues; proper diagnosis and repair are essential for efficiency.
Error Code E12: Detailed Analysis & Fixes
The Lochinvar E12 error code signifies a critical issue with the combustion process, specifically a failure to achieve ignition within a specified timeframe. This often points to problems with the gas supply, ignition system, or flame sensing. A simplified troubleshooting approach begins with verifying adequate gas pressure at the boiler. Subsequently, inspect the igniter for visible damage or weakness; replacement may be necessary if compromised.

Crucially, examine the flame sensor for cleanliness and proper grounding – a dirty or poorly grounded sensor frequently triggers false E12 codes. Ensure all wiring connections are secure and free from corrosion. If the issue persists, a deeper dive into the control board functionality might be required, potentially indicating a faulty board. Remember to always prioritize safety and consult a qualified technician if you are uncomfortable performing these checks.
Alternating ARHL and MRHL Codes: Ignition & Flame Detection
The frustrating cycle of alternating ARHL (Air Restriction High Limit) and MRHL (Manual Reset High Limit) codes on a Lochinvar Knight boiler almost always indicates a persistent ignition or flame detection problem. The boiler is attempting to ignite, reaching a high limit, and then shutting down, repeating the cycle. Initial troubleshooting should focus on the flame sensor; cleaning or replacing it is often the first successful step.
Next, thoroughly inspect the igniter for proper operation and visible damage. Verify the gas valve is opening and closing correctly. A weak or failing igniter can struggle to establish a stable flame, triggering these codes. Check for proper venting and airflow, as restricted airflow can mimic these symptoms. If these steps don’t resolve the issue, a professional diagnosis of the control board is recommended.
Low Flame Signal: Grounding Issues & Solutions
A consistently low flame signal on your Lochinvar boiler frequently points towards grounding problems within the system, particularly in Crest models. The signal strength is directly affected by the electrical connection between the boiler components and the ground. A simple, yet effective, diagnostic step is to add a dedicated ground wire. If the flame signal noticeably increases after adding the ground, you’ve identified the root cause – a poor grounding connection.
Inspect all grounding wires and connections for corrosion or looseness. Ensure the boiler is properly bonded to the building’s grounding system. A multimeter can be used to verify continuity between the boiler chassis and ground. If the grounding remains inadequate, consult a qualified technician to assess the electrical system and implement a robust grounding solution.
Lockout Codes: Identifying the Root Cause
Lochinvar boilers utilize lockout codes to signal a critical failure requiring immediate attention. These codes indicate the unit has shut down to prevent damage or unsafe operation. Identifying the specific lockout code is the first step in troubleshooting. Refer to your Lochinvar manual’s error code table (Table 4-2) for a detailed explanation of each code’s meaning.
Common causes include ignition failures, flame rollout, high limit switch activation, or issues with the gas supply. Before resetting the boiler, address the underlying problem. Repeated lockouts suggest a persistent issue needing professional diagnosis. Ignoring lockout codes can lead to further damage and potentially hazardous conditions. Always prioritize safety and consult a qualified technician if unsure.
Blocking Codes: Operational Interruptions
Lochinvar blocking codes signify operational interruptions that don’t necessarily require a complete shutdown like lockout codes, but prevent the boiler from functioning normally. These codes indicate a temporary issue hindering performance, often allowing the unit to resume operation once the problem is resolved. Examples include low water pressure, insufficient airflow, or a call for heat that isn’t being met.
Unlike lockouts, blocking codes often allow for a reset attempt after addressing the identified issue. However, frequent blocking codes point to an underlying problem needing investigation. Consult the Lochinvar manual’s error code table for specific code definitions and recommended corrective actions. Ignoring blocking codes can lead to reduced efficiency or eventual lockout situations.
Notification Codes: Unit Status While Running
Lochinvar notification codes are displayed while the unit is actively running and indicate the current operational status, rather than a fault condition requiring immediate attention. These codes provide valuable insights into the boiler’s performance, such as reporting normal operational parameters or confirming successful completion of a cycle. They don’t initiate a shutdown or lockout, allowing continued operation.
Examples might include codes indicating the boiler is in pre-heat, post-purge, or is actively firing. While not critical errors, monitoring notification codes can help identify potential developing issues or confirm proper system function. Refer to the specific Lochinvar model’s documentation to fully understand the meaning of each notification code and its implications for overall system health and efficiency.

Specific Lochinvar Model Troubleshooting
This section details troubleshooting steps tailored for specific Lochinvar models – Knight, Copper-Fin II/IIE, Crest, and pool heaters – addressing unique issues.
Lochinvar Knight Boiler Troubleshooting
The Lochinvar Knight boiler, a popular choice, often presents alternating ARHL and MRHL error codes, signaling ignition or flame detection problems. A primary focus should be on the flame sensor; inspect it for cleanliness and proper grounding. If the flame signal is consistently low, adding a dedicated ground wire can often resolve the issue, particularly in Crest models as well.
Lockout codes require identifying the root cause – is it a gas supply issue, a faulty igniter, or a problem with the control board? Regularly check for fault messages displayed on the operator interface, as these provide valuable clues. Remember to consult the Lochinvar manual for specific error code definitions and recommended actions. Proper gas safety considerations are paramount during any troubleshooting procedure.
Lochinvar Copper-Fin II/IIE Boiler Troubleshooting
Troubleshooting the Lochinvar Copper-Fin II/IIE boiler often involves interpreting fault messages displayed on the operator interface. Utilize the troubleshooting charts provided in the Lochinvar manual to correlate these messages with potential corrective actions. Common issues include failed temperature sensors, requiring checks and potential calibration. Sensor tables within the manual detail expected values for accurate diagnosis.
Pay close attention to lockout, blocking, and notification error codes, as outlined in the operating information section of the manual. These codes indicate operational interruptions or unit status while running. When encountering a “no display” issue, systematically check power supply and control board connections. Remember to prioritize safety and consult qualified, Gas Safe registered engineers for complex repairs.
Lochinvar Crest Boiler Troubleshooting
The Lochinvar Crest boiler, like other models, can exhibit low flame signal issues. A crucial step in diagnosis is checking for grounding problems; adding a ground wire can often resolve this, particularly if the signal improves. This is a common fix for both Crest and similar boiler models. When facing ignition or flame detection problems, carefully inspect the flame sensor and igniter for any signs of damage or malfunction.
Refer to the Lochinvar manual for specific error codes related to lockouts, blocking, and notifications. These codes provide valuable clues about the root cause of the issue. Remember to prioritize safety when working with gas and electrical components, and always consult a qualified, Gas Safe registered engineer for complex repairs or if you are unsure about any procedure.
Lochinvar Pool Heater Troubleshooting
When troubleshooting a Lochinvar pool heater, communication issues over Modbus are a potential concern. Begin by systematically checking all connections and settings related to Modbus communication. Review the manual for specific troubleshooting steps related to Modbus, ensuring all parameters are correctly configured. Additionally, consult the troubleshooting charts for fault messages displayed on the operator interface, as these provide direct insights into the problem.
Pay close attention to any error codes displayed, referencing the manual’s section on lockout, blocking, and notification codes. These codes are essential for pinpointing the source of the malfunction. Remember to prioritize safety and, if unsure, contact Lochinvar support or a registered engineer.

Component-Specific Troubleshooting
Focus on diagnosing issues with the flame sensor, igniter, and temperature sensors; checking and calibrating these components is crucial for optimal Lochinvar performance.
Flame Sensor Issues & Diagnostics
A malfunctioning flame sensor is a frequent cause of ignition and flame detection problems, often manifesting as alternating ARHL and MRHL codes on Lochinvar Knight boilers. Thoroughly inspect the flame sensor for any signs of corrosion or buildup, as contaminants can impede its ability to accurately detect the flame. Cleaning the sensor with fine steel wool or a specialized sensor pad is often the first step in resolving the issue.
If cleaning doesn’t resolve the problem, consider checking the grounding. A low flame signal can sometimes be traced back to grounding issues; adding a ground wire may improve the signal. Furthermore, ensure the sensor is properly positioned within the flame path. Incorrect placement can lead to intermittent or false readings. Use a multimeter to test the sensor’s continuity and resistance, comparing the results to the manufacturer’s specifications. A faulty sensor will require replacement with a compatible Lochinvar part.
Igniter Problems & Replacement
When encountering ignition failures with your Lochinvar boiler, the igniter is a prime suspect. Initial diagnostics should involve visually inspecting the igniter for cracks or damage. A compromised igniter may not generate a sufficient spark to ignite the gas. Verify the igniter is receiving proper voltage; a lack of power indicates an electrical issue upstream, potentially with the control board or wiring.
If the igniter appears physically sound and receives voltage but fails to ignite the gas, replacement is typically necessary. Always disconnect power before handling the igniter. Ensure the replacement igniter is a direct Lochinvar-approved part to guarantee compatibility and optimal performance. After installation, re-test the ignition sequence to confirm the issue is resolved. Persistent ignition problems after igniter replacement may point to other underlying issues, such as gas supply problems or a faulty gas valve.
Temperature Sensor Checks & Calibration
Accurate temperature readings are crucial for efficient Lochinvar boiler operation. Begin by visually inspecting temperature sensors for any physical damage or corrosion. Use a multimeter to check the sensor’s resistance; compare the reading to the values specified in the Lochinvar service manual for your specific model. Deviations from the expected range indicate a faulty sensor requiring replacement.
Some Lochinvar models allow for temperature sensor calibration through the control board interface. Consult the manual for the correct calibration procedure. Incorrect calibration can lead to inaccurate temperature control and reduced efficiency. After replacing or calibrating a temperature sensor, monitor the boiler’s performance to ensure proper heating and temperature regulation. Regularly checking sensor readings is a proactive maintenance step.

Advanced Troubleshooting Techniques
Delve into Modbus communication issues, analyze complex fault messages displayed on the operator interface, and master effective troubleshooting table utilization for optimal results.
Modbus Communication Troubleshooting
When encountering communication problems with your Lochinvar system via Modbus, a systematic approach is crucial. Begin by verifying the physical connections – ensure all wiring is secure and correct. Confirm that the Modbus addresses are correctly configured on both the Lochinvar unit and the controlling device, such as a building automation system.
Next, check the baud rate, parity, and stop bits to guarantee they match across all devices. Utilize Modbus diagnostic tools to test communication integrity and identify potential errors. Inspect for any network conflicts or interference that might disrupt the signal. If issues persist, consult the Lochinvar documentation for specific Modbus mapping details and troubleshooting steps. Remember to document all changes made during the troubleshooting process for future reference and potential escalation to Lochinvar support.
Analyzing Fault Messages on the Operator Interface
The Lochinvar operator interface provides valuable insights into system performance through displayed fault messages. When a fault message appears, carefully note the exact wording and any associated error codes. These codes are key to pinpointing the source of the problem. Consult the Lochinvar manual’s troubleshooting charts, specifically those detailing fault messages displayed on the boiler interface, to decipher the meaning of each message.
Understand that fault messages can indicate anything from sensor failures to operational interruptions. Don’t simply clear the message; investigate the underlying cause. Utilize the provided corrective actions listed alongside each fault message in the manual. Document the fault message, the steps taken to resolve it, and the outcome for future reference and potential support requests. A methodical approach to analyzing these messages is essential for efficient troubleshooting.
Using Troubleshooting Tables Effectively
Lochinvar manuals contain comprehensive troubleshooting tables designed to streamline the diagnostic process. These tables correlate symptoms, error codes (lockout, blocking, and notification), and potential corrective actions. When utilizing these tables, begin by accurately identifying the observed symptom or error code displayed on the operator interface;

Follow the table’s logic systematically, checking each suggested item in the order presented. Don’t skip steps, as seemingly unrelated checks can reveal the root cause. Pay close attention to sensor tables for temperature sensor checks and calibration procedures. Document each test performed and its result, even if negative. Effective use of these tables requires patience and a methodical approach, ensuring a thorough investigation before resorting to component replacement. Remember to always prioritize safety precautions.

Safety Precautions & Best Practices
Prioritize gas and electrical safety during all Lochinvar troubleshooting. Disconnect power and gas before servicing, and always consult the manual for guidance.
Gas Safety Considerations

Working with gas appliances requires utmost caution. Before initiating any troubleshooting on your Lochinvar system, ensure the gas supply is completely shut off at the main valve. Always verify the absence of gas leaks using a suitable leak detection solution – never rely on smell alone.
Proper ventilation is crucial; ensure the work area is well-ventilated to prevent gas accumulation. If you detect any gas odor during troubleshooting, immediately cease work, evacuate the area, and contact your local gas company or a qualified gas engineer. Never attempt to repair gas lines yourself; this should only be performed by certified professionals.
Be mindful of potential ignition sources, such as open flames or sparks, while working near gas connections. Regularly inspect gas lines and connections for corrosion, damage, or leaks. Adhering to these safety measures will help prevent hazardous situations and ensure a safe working environment.
Electrical Safety Guidelines
Prioritize electrical safety when troubleshooting your Lochinvar boiler. Always disconnect power to the unit at the circuit breaker before accessing any electrical components. Verify the power is off using a reliable voltage tester – do not assume. Never work on live electrical circuits.
Inspect wiring for damage, fraying, or loose connections. Replace any damaged wires immediately. Ensure all electrical connections are tight and secure. Be aware of grounding issues, as these can contribute to low flame signals and operational problems. Use insulated tools designed for electrical work.
If you are uncomfortable working with electrical components, consult a qualified electrician. Improper electrical work can lead to shocks, fires, and damage to the boiler. Always follow local electrical codes and regulations.

Resources & Further Support
Access Lochinvar manuals and documentation online for detailed information. Contact Lochinvar support or a registered engineer for expert assistance and service.
Lochinvar Manuals & Documentation
Comprehensive documentation is crucial for effective Lochinvar troubleshooting. Lochinvar provides extensive manuals online, covering a wide range of models including the Knight, Copper-Fin II/IIE, and Crest boilers, as well as pool heaters. These resources detail error codes – lockout, blocking, and notification types – offering corrective actions for each.
You’ll find tables outlining troubleshooting steps for issues like a blank display, and detailed sensor checks with corresponding sensor tables. Furthermore, manuals include troubleshooting charts displaying fault messages on the operator interface, specific to models like the Copper-Fin II/IIE and pool heaters. Accessing these documents allows for a deeper understanding of system operation and facilitates accurate diagnosis and repair, ultimately minimizing downtime and maximizing efficiency. Always refer to the specific manual for your Lochinvar model.
Contacting Lochinvar Support & Registered Engineers
When self-troubleshooting proves insufficient, contacting Lochinvar support or a registered engineer is vital. Lochinvar offers dedicated support channels to assist with complex issues and error code interpretation. For urgent matters, particularly those involving gas safety, engaging a Gas Safe Registered Engineer is paramount.
These professionals possess specialized knowledge of Lochinvar systems and can accurately diagnose and resolve problems, ensuring safe and compliant operation. Many firms advertise expert boiler service with same-day appointments. Remember, attempting repairs without proper training can be dangerous and may void warranties. Prioritize safety and rely on qualified personnel for any work beyond basic troubleshooting steps. Access to 24/7 support is often available for critical system failures.